rule1 on Rules#Timer=1 do power3 off endon rule2 on button1#state=10 do power3 toggle endon on button2#state=10 do power3 toggle endon rule3 on button3#state=10 do backlog power3 toggle; ruletimer1 600 endon on button3#state=11 do backlog power3 toggle; ruletimer1 3600 endon on button3#state=12 do backlog power3 toggle; ruletimer1 14400 endon backlog rule1 1;rule2 1; rule3 1; setoption1 1; setoption13 0; setoption32 60; setoption73 1
rule1 on Rules#Timer=1 do power3 off endon rule2 on button1#state=10 do power3 toggle endon on button2#state=10 do power3 toggle endon rule3 on button3#state=10 do backlog power3 toggle; ruletimer1 600 endon on button3#state=11 do backlog power3 toggle; ruletimer1 3600 endon on button3#state=12 do backlog power3 toggle; ruletimer1 14400 endon backlog rule1 1;rule2 1; rule3 1; setoption1 1; setoption13 0; setoption32 60; setoption73 1
List of button states
10=1 short press
11=2 short press
12=3 short press
13=4 short press
14=5 short press
3=LONG press